- Braided Wire
Page 1 of 3
Brand |
: |
RS PRO |
MFR # |
: |
358-012 |
Size |
: |
4 x 0.8 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
1.7 mm² |
Current Rating |
: |
30 A |
Length |
: |
25m |
Conductor Resistance |
: |
10.44 Ω/km |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
358-006 |
Size |
: |
1.9 x 0.6 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
0.5 mm² |
Current Rating |
: |
10 A |
Length |
: |
25m |
Conductor Resistance |
: |
35 Ω/km |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
365-543 |
Size |
: |
10 x 2 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
7.5 mm² |
Current Rating |
: |
63 A |
Length |
: |
25m |
Conductor Resistance |
: |
2.349 Ω/km |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
365-559 |
Size |
: |
24 x 12 x 0.20 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
9.05 mm² |
Current Rating |
: |
90 A |
Length |
: |
25m |
Conductor Resistance |
: |
1.91 Ω/km |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-210 |
Size |
: |
24 x 20 x 0.2 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
10.05 mm² |
Length |
: |
150mm |
Conductor Resistance |
: |
1762 Ω/km |
Stud Size |
: |
M6 |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-163 |
Size |
: |
24 x 20 x 0.2 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
15.08 mm² |
Length |
: |
0.25m |
Conductor Resistance |
: |
1174 Ω/km |
Stud Size |
: |
M6 |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-169 |
Size |
: |
24 x 20 x 0.2 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
15.08 mm² |
Length |
: |
0.4m |
Conductor Resistance |
: |
1174 Ω/km |
Stud Size |
: |
M6 |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-208 |
Size |
: |
16 x 20 x 0.2 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
10.05 mm² |
Length |
: |
0.15m |
Conductor Resistance |
: |
1762 Ω/km |
Stud Size |
: |
M5 |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-191 |
Size |
: |
Dia 0.2 mm |
Conductor Material |
: |
Tinned Copper |
Length |
: |
0.2m |
Conductor Resistance |
: |
2349 Ω/km |
Stud Size |
: |
M5 |
Cable Shape |
: |
Earth Lead |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-185 |
Size |
: |
16 x 8 x 0.15 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
2.26 mm² |
Length |
: |
0.2m |
Conductor Resistance |
: |
7830 Ω/km |
Stud Size |
: |
M8 |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-175 |
Size |
: |
16 x 4 x 0.15 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
1.13 mm² |
Length |
: |
0.15m |
Conductor Resistance |
: |
15.41 Ω/km |
Stud Size |
: |
M3.5 |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-197 |
Size |
: |
16 x 20 x 0.2 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
10.05 mm² |
Length |
: |
0.1m |
Conductor Resistance |
: |
1762 Ω/km |
Stud Size |
: |
M5 |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-214 |
Size |
: |
16 x 20 x 0.2 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
10.05 mm² |
Length |
: |
0.2m |
Conductor Resistance |
: |
1762 Ω/km |
Stud Size |
: |
M5 |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-157 |
Size |
: |
2 x 24 x 16 x 0.2 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
24.13 mm² |
Length |
: |
0.4m |
Conductor Resistance |
: |
0.722 Ω/km |
Stud Size |
: |
M8 |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-153 |
Size |
: |
3 x 2 x 16 x 0.2 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
36.19 mm² |
Length |
: |
0.5m |
Conductor Resistance |
: |
0.481 Ω/km |
Stud Size |
: |
M8 |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-204 |
Size |
: |
24 x 11 x 0.2 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
8.29 mm² |
Length |
: |
0.15m |
Conductor Resistance |
: |
2.1 Ω/km |
Stud Size |
: |
M5 |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-179 |
Size |
: |
16 x 4 x 0.15 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
1.13 mm² |
Length |
: |
0.1m |
Conductor Resistance |
: |
15.41 Ω/km |
Stud Size |
: |
M3.5 |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
RS PRO |
MFR # |
: |
489-181 |
Size |
: |
16 x 4 x 0.15 mm |
Conductor Material |
: |
Tinned Copper |
Cross Sectional Area |
: |
1.13 mm² |
Length |
: |
0.2m |
Conductor Resistance |
: |
15659 Ω/km |
Stud Size |
: |
M3.5 |
Cable Shape |
: |
Single Core |
Standards Met |
: |
BS EN 13602:2002, BS4109 |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
MBJ16-100-6 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
16 mm² |
Current Rating |
: |
120 A |
Length |
: |
100mm |
Stud Size |
: |
6.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
563550 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
16 mm² |
Current Rating |
: |
120 A |
Length |
: |
150mm |
Stud Size |
: |
6.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
MBJ16-200-6 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
16 mm² |
Current Rating |
: |
120 A |
Length |
: |
200mm |
Stud Size |
: |
6.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
MBJ16-300-6 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
16 mm² |
Current Rating |
: |
120 A |
Length |
: |
300mm |
Stud Size |
: |
6.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
556620 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
16 mm² |
Current Rating |
: |
120 A |
Length |
: |
100mm |
Stud Size |
: |
8.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
556630 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
16 mm² |
Current Rating |
: |
120 A |
Length |
: |
150mm |
Stud Size |
: |
8.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
556640 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
16 mm² |
Current Rating |
: |
120 A |
Length |
: |
200mm |
Stud Size |
: |
8.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
556650 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
16 mm² |
Current Rating |
: |
120 A |
Length |
: |
250mm |
Stud Size |
: |
8.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
556660 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
16 mm² |
Current Rating |
: |
120 A |
Length |
: |
300mm |
Stud Size |
: |
8.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
556940 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
16 mm² |
Current Rating |
: |
120 A |
Length |
: |
500mm |
Stud Size |
: |
8.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
556680 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
25 mm² |
Current Rating |
: |
150 A |
Length |
: |
150mm |
Stud Size |
: |
10.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
556690 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
25 mm² |
Current Rating |
: |
150 A |
Length |
: |
200mm |
Stud Size |
: |
10.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
556700 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
25 mm² |
Current Rating |
: |
150 A |
Length |
: |
250mm |
Stud Size |
: |
10.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
556710 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
25 mm² |
Current Rating |
: |
150 A |
Length |
: |
300mm |
Stud Size |
: |
10.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
563430 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
25 mm² |
Current Rating |
: |
150 A |
Length |
: |
200mm |
Stud Size |
: |
12.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
563340 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
25 mm² |
Current Rating |
: |
150 A |
Length |
: |
200mm |
Stud Size |
: |
6.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
555200 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
25 mm² |
Current Rating |
: |
150 A |
Length |
: |
200mm |
Stud Size |
: |
8.5 mm |
Standards Met |
: |
cUL, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
555201 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
25 mm² |
Current Rating |
: |
150 A |
Length |
: |
300mm |
Stud Size |
: |
8.5 mm |
Standards Met |
: |
cUL, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
556720 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
30 mm² |
Current Rating |
: |
180 A |
Length |
: |
100mm |
Stud Size |
: |
10.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
MBJ30-200-10 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
30 mm² |
Current Rating |
: |
180 A |
Length |
: |
200mm |
Stud Size |
: |
10.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
MBJ30-300-10 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
30 mm² |
Current Rating |
: |
180 A |
Length |
: |
300mm |
Stud Size |
: |
10.5 mm |
Standards Met |
: |
RoHS, UL |
|
Brand |
: |
nVent ERIFLEX |
MFR # |
: |
534407 |
Fire Behaviour |
: |
UL 94 V0 / V2 |
Conductor Material |
: |
Copper |
Cross Sectional Area |
: |
50 mm² |
Current Rating |
: |
250 A |
Length |
: |
230mm |
Stud Size |
: |
8.5 mm, 10.5 mm |
Standards Met |
: |
CE, CSA |
|